二维搜索
Sketch the part you are looking for or have a photo described in text form
Create image description with AI
Create image description with AI
Drop file here
支持的文件格式: .PNG, .JPG, .JPEG, .WEBP
1/5
1
1
2|0
3
4
4
0
0
0
0
0
0
0
0
0
0

72A100000501

Expand Table
EN
1/5
预览图
PREVIEWPERLINE
EF000003
VAR17
Code
CODE
Description
VAR0
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
720182405002
Type 72. 01 level control relay for conductive liquids with adjustable sensitivity (5 … 150) kΩ, selectable intervention delay (0. 5 s or 7 s). Filling or emptying function switch selectable. This control relay is also available for 400 V supply. The adjustable sensitivity (5… 450) kΩ version can also be equipped with a contact for low loads down to 5 V – 1 mA. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2 / 50 µs) between: , – power supply and contacts, – probes and power supply, – contacts and probes, Assembly on 35 mm rail (EN 60715), Control of a single level or two levels Min / Max
720184000000
Type 72. 01 level control relay for conductive liquids with adjustable sensitivity (5 … 150) kΩ, selectable intervention delay (0. 5 s or 7 s). Filling or emptying function switch selectable. This control relay is also available for 400 V supply. The adjustable sensitivity (5… 450) kΩ version can also be equipped with a contact for low loads down to 5 V – 1 mA. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2 / 50 µs) between: , – power supply and contacts, – probes and power supply, – contacts and probes, Assembly on 35 mm rail (EN 60715), Control of a single level or two levels Min / Max
720190240000
Type 72. 01 level control relay for conductive liquids with adjustable sensitivity (5 … 150) kΩ, selectable intervention delay (0. 5 s or 7 s). Filling or emptying function switch selectable. This control relay is also available for 400 V supply. The adjustable sensitivity (5… 450) kΩ version can also be equipped with a contact for low loads down to 5 V – 1 mA. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2 / 50 µs) between: , – power supply and contacts, – probes and power supply, – contacts and probes, Assembly on 35 mm rail (EN 60715), Control of a single level or two levels Min / Max
721180240000
Type 72. 11 Level control relays for conductive liquids are equipped with a fixed sensitivity of 150 kΩ, a fixed tripping delay of 1s, with filling or emptying function selectable via an external jumper link. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2/50 µs) between: , – Power supply and contacts, – Probes and power supply, – Contacts and probes, 35 mm rail (EN 60715) mounting, Control of about a single level or between Min/Max levels
721181250000
Type 72. 11 Level control relays for conductive liquids are equipped with a fixed sensitivity of 150 kΩ, a fixed tripping delay of 1s, with filling or emptying function selectable via an external jumper link. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2/50 µs) between: , – Power supply and contacts, – Probes and power supply, – Contacts and probes, 35 mm rail (EN 60715) mounting, Control of about a single level or between Min/Max levels
721182400000
Type 72. 11 Level control relays for conductive liquids are equipped with a fixed sensitivity of 150 kΩ, a fixed tripping delay of 1s, with filling or emptying function selectable via an external jumper link. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2/50 µs) between: , – Power supply and contacts, – Probes and power supply, – Contacts and probes, 35 mm rail (EN 60715) mounting, Control of about a single level or between Min/Max levels
721190240000
Type 72. 11 Level control relays for conductive liquids are equipped with a fixed sensitivity of 150 kΩ, a fixed tripping delay of 1s, with filling or emptying function selectable via an external jumper link. Features include: Filling and emptying functions, LED indicator, Double insulation (6 kV – 1. 2/50 µs) between: , – Power supply and contacts, – Probes and power supply, – Contacts and probes, 35 mm rail (EN 60715) mounting, Control of about a single level or between Min/Max levels
724200240000
Type 72. 42 Control relays for alternating loads such as with pumps, compressors, air conditioning and refrigeration units, so as to share the duty and standby function and thereby even out the wear across the equipment. It is a Multi-function relay (4 MI, ME, M2, M1 functions) with 2 independent NO contacts, 12 A outputs, 2 start inputs, isolated from the power supply. Features include: Supply voltage: 110 … 240 V and 24 V AC/DC, Modular relay, 35 mm wide, 35 mm rail (EN 60715), Cadmium-free contacts
724202300000
Type 72. 42 Control relays for alternating loads such as with pumps, compressors, air conditioning and refrigeration units, so as to share the duty and standby function and thereby even out the wear across the equipment. It is a Multi-function relay (4 MI, ME, M2, M1 functions) with 2 independent NO contacts, 12 A outputs, 2 start inputs, isolated from the power supply. Features include: Supply voltage: 110 … 240 V and 24 V AC/DC, Modular relay, 35 mm wide, 35 mm rail (EN 60715), Cadmium-free contacts
Flush mounted (plaster)
72A100000500
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100000501
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100000502
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100001000
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100001001
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100001002
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100001500
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100001502
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100002000
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
Flush mounted (plaster)
72A100002001
Type 72. A1. 0000. xxxx float level switch with double sealed chamber suitable for controlling the level of fluids in grey and waste water systems. Supplied with a counterweight (230 g) and cable gland. Also available: Type 72. A1. 0000. xx02 – float level switch with double sealed chamber for liquid foodstuff and potable water, it is also suitable for liquids with high chlorine content and/or high salinity. Supplied with counterweight (230 g) and cable gland made with ACS certified cable and plastics for food use. Features include: Changeover contact, 10 A (resistive load), 8 A (inductive load), Double sealed chambers resistant to high pressure, Cable length 5 m, 10 m, 15 m or 20 m, Can be used for both emptying and filling applications, AgNi contact material
显示压缩表示形式 (36 Produkt)
订购编码72A100000501
ShorttextLevel control relays
上次修改27.05.2022 12:25:12
单位

分类

CNS

CNSERPBASE Object Properties
Order Number72A100000501